The Flow Component Testing Facilities (FCTF) at SwRI are accredited through the American Petroleum Institute (API) to perform validation testing on both surface and subsurface safety valves. The facilities are also used to perform safety valve testing on other downhole safety valves, riser isolation valves, and wellhead valves. All testing is completed under an API Q1 and ISO 17025 quality management system.
Safety Valve Testing Services
API 14A Subsurface Safety Valves (SSSV)
SwRI performs SSSV testing on surface control safety valves (SCSSV) and subsurface control safety valves (SSCSV), subsurface injection safety valves (SSISV), and annular safety valves.
- Validation Testing – Annex B
- Functional Testing – Annex C
- Operating Life Testing, Differential Opening – Annex G
- Extended Sand Endurance Testing – Annex I
- High Rate Gas Slam Closure Testing – Annex K
- Experimental Flow and Integrity Testing
- Extreme Cold Operating Life Test
API 14A Annex B Subsurface Safety Valve Validation Test Application
API Safety Valve Validation Testing
API 6AV1 Wellhead Surface Safety Valves & Underwater Safety Valve for Offshore Service
SwRI performs testing on various types of valves used as underwater safety valves (USV), surface safety valves (SSV), and boarding shutdown valves (BDSV). This equipment is essential for emergency shutdown of offshore production.
API Spec. 6AV1 Surface Safety Valve Test Application
API 6A-PR2 testing is performed within the Structural Engineering Department at SwRI.
API 19V and API 17G tests can be found in Downhole Completion & Subsea Valve Testing.
Quality Control & Testing
All third-party testing activities performed at the Flow Component Testing Facilities (FCTF) are subject to compliance with the FCTF Quality Manual, which conforms to the safety and quality requirements outlined in the following documents:
- API specification Q1, specification for quality programs for the petroleum, petrochemical, and natural gas industry
- ISO 9001, quality management systems
- ISO/IEC 17025, general requirements for the competence of testing and calibration laboratories
- ISO 45001, occupational health and safety management systems
- ISO 14001, environmental management systems
Flow Component Test Facilities ISO 14001 Accreditation
SwRI is registered with ISO for ISO 14001 as it applies to work performed in the Flow Component Testing Facilities. (Registration No. C0317387-EM5)
API Testing Accreditation
SwRI is registered with API for API Specification Q1 as it applies to third party validation testing services per specifications API 14A and API 6AV1 (Registration No. Q1-3729).